| If you inspect… | Start with | Why |
|---|---|---|
| 12-inch wafers, photomasks, panels | STMT12-BD | 356 × 305 mm travel; 12 MP documentation camera; motorised turret option |
| 8-inch wafers, 200 mm frames | STMT80-BD | 210 × 210 mm travel in a bench-sized footprint |
| 6-inch wafers, MEMS, compound semi | STMT60-BD | 158 × 158 mm travel; erect image for recipe consistency |
| Polished mounts, coatings, DIC work | STMT40-BD | BF / DF / POL / DIC from one illuminator; 6″ × 4″ stage |
| Heavy or irregular parts | STME500 | Inverted stand — specimen sits on the stage, no height limit |
| Inclusions and fine scratches | STME700 | Bright/dark-field switching unit in the stand |
| Accredited lab, highest resolution | STRX63M | CFI60 TU Plan Fluor BD objectives, WD 18 mm at 5× |
| Minerals, crystals, polymers | STCX43P | 160 mm rotating stage, 6′ accuracy, Bertrand lens |
| Opaque ores + thin sections | STCX43MP | Transmitted polarizing plus reflected bright field |
Choose inverted when specimens are heavy, irregular or taller than the stage opening, or when you want to place a polished mount directly on the stage without clamping. Choose upright when you need maximum optical flexibility (transmitted light, polarizing accessories, DIC) or work mostly with thin sections and small mounts.
At least 356 mm in X and 305 mm in Y to reach the full surface without re-chucking — that is the STMT12-BD table (710 × 420 mm). For 8-inch wafers, 210 × 210 mm is sufficient (STMT80-BD); for 6-inch, 158 × 158 mm (STMT60-BD).
Yes, for non-metallic inclusions and fine surface defects. Dark field renders low-contrast scatterers bright against a dark background, which is how inclusion rating to ISO 4967 / ASTM E45 is normally performed. A bright-field-only stand will under-report.
It tells the software which objective is in the light path, so the measurement calibration changes automatically when the objective changes. Without it, an operator can measure with the wrong scale — the most common error in metallographic reporting.
Yes. The wafer and research platforms ship with a 12 MP industrial camera, a brand PC and monitor, and ST-1.5D measurement software including stitching and extended depth of focus. The inverted models are supplied with C-mount ports for 5–20 MP cameras and the matching software suites.
Yes — mechanical configuration, silkscreen, packaging and software branding can be adapted for volume orders. Send your requirement and expected annual quantity for an OEM quotation.
Sectioning, mounting, grinding and polishing sequence — and how preparation defects are mistaken for material defects.